air pressure transducer
Range: -0.1~0~1~150(MPa) Range optional
Comprehensive accuracy: 0.1% FS, 0.25% FS, 0.5% FS
Output signal: 4~20mA (two-wire system), 0~5V, 1~5V, 0~10V (three-wire system), RS485 (digital signal)
Supply voltage: 24VDC (9 ~ 36VDC)
Medium temperature: -20~85°C (normal temperature type) -20~200°C (medium temperature type) -20~600°C (high temperature type)
Ambient temperature: normal temperature (-20 ~ 85 ° C)
Zero temperature drift: ≤±0.05%FS°C
Range temperature drift: ≤±0.05%FS°C
Compensation temperature: 0~70°C
Safety overload: 150% FS
Extreme overload: 200% FS
Response time: 5 mS (up to 90% FS)
Load resistance: Current output type: maximum 800Ω; voltage output type: greater than 5KΩ
Insulation resistance: greater than 2000MΩ (100VDC)
Sealing level: IP65
Long-term stability: 0.1% FS / year
Vibration effect: The output changes less than 0.1% FS within the mechanical vibration frequency of 20Hz~1000Hz.
Electrical interface (signal interface): Hessmann connector + four core shielded cable
Mechanical connection (threaded interface): M20×1.5, etc., other threads can be designed according to customer requirements
Related content
pressure indicator
pressure indicator
air pressure transd
air pressure transd
hydraulic pressure
hydraulic pressure
static pressure sen
static pressure sen
pressure measuremen
pressure measuremen
liquid pressure sen
liquid pressure sen
low pressure sensor
low pressure sensor
pressure transmitte
pressure transmitte
dp transmitter
dp transmitter
pressure indicator
pressure indicator
gas pressure sensor
gas pressure sensor
low pressure transd
low pressure transd
[Back]      [Close]
Home    |    About Us    |    News    |    Products    |    Authenticotion    |    Order    |    Message    |    XML
Link: yunyiyibiao
China Xian yun yi Instrument Co., Ltd. Consult product information: Pressuregage7@hotmail.com Power by DedeCms